Available options for each model are indicated on the individual product pages.

PNEUMATIC OPTIONS  

-BPL Bottom Push Lock connections. The input/output manifold is mounted on the bottom of the control with the push lock fittings installed.

 -C Cancelable Output. When the two-hand control is activated a pneumatic signal is given, while the buttons are continued to be held, a signal is sent back to the two-hand control, port -C, and cancels the output signal. The output remains canceled after the cancel signal is removed until the buttons are released and pressed again.

-P .5 second pulsed output. When the buttons are pressed the output signal is given for .5 seconds and turns off even though the buttons are continued to be held.

-PA An Adjustable timer 1-20 seconds adjustable. When the buttons are pressed the output is given for a set time and turns off and vents even though the buttons are continued to be held. If the buttons are released before the time elapses the signal will turn off and vent.

-B Bottom connections. Connections on bottom of manifold.

-EPB Extra push button. A center mounted pushbutton N/C 3-way valve. This shares the pneumatic supply with the logic and has a separate output marked -EPB

-SWV Switch Valve. A toggle type 2 position diverter valve to divert the two-hand signal between two output ports. If the operator sets the diverter valve to the “A” position and presses the two-hand buttons a signal is given out the “A” port. If the operator sets the diverter valve to the “B” position and presses the two-hand buttons a signal is given out the “B” port.

 

ELECTRIC OPTIONS

 -K The black and white wires in the output cord are wired to a contact that is closed when the control is activated. This is recommended for connection to a PLC.

-C Cancelable Output. A two wire cord is added to the control. The two wires are connected to a normally closed switch (not included). When the control is activated and held the output signal is given until the cancel switch is opened. When the cancel switch is opened the output signal is canceled. The output signal remains canceled when the cancel switch is closed. The cancel switch must be closed and the buttons released and reapplied to obtain another output signal.

– G Button Guards. Guards that surround the buttons and extend in place of the standard 1/4”, model REN44 only.

-P .5 second pulsed output. When the buttons are pressed the output is given for .5 seconds and turns off and vents even though the buttons are continued to be held.

-PA An adjustable timer 1-1023 seconds adjustable. When the buttons are pressed the output signal is given for a set time and turns off even though the buttons are continued to be held. If the buttons are released before the time elapses the signal will turn off.

-EPB Extra push button. A center mounted red momentary pushbutton with 1 N/C contact and 1 N/O contact wired thru a cord marked EPB.

 -EPBMN Extra push button. A center mounted red maintained push/pull button with 1 N/C contact and 1 N/O contact wired thru a cord marked EPB.